AC vaccum pump refrigeration CHINAMFG vacuum pump
We can supply many kinds of   CHINAMFG Vaccum Pump,Pump,Vacuum Pump , Vacuum Pump,Two Stage Vacuum Pump,One Stage Vacuum Pump,two stage vacuum pump (high speed) , 2 Stage Vacuum Pump,Double Stage Vacuum Pump,Single Stage Pump

  SINGLE STAGE DUAL STAGE
MODEL VE115 VE125 VE215 VE225
FLOW RATE 50HZ 1.5CFM 2.5CFM 1.5CFM 2.5CFM
42L/MIN 70L/MIN 42L/MIN 70L/MIN
60HZ 1.8CFM 3CFM 1.8CFM 3CFM
50L/MIN 84L/MIN 50L/MIN 84L/MIN
ULTIMATE VACUUM 5PA 5PA 3X10-1PA 3X10-1PA
0.05MBAR 0.05MBAR 25MICRON 25MICRON
POWER 1/4HP 1/4HP 1/4HP 1/3HP
INLET PORT 1/4″FLARE 1/4″FLARE 1/4″FLARE 1/4″FLARE
OIL CAPACITY 310ML 310ML 200ML 250ML
DIMENSIONS 285X124X230MM 285X124X230MM 308X124X230MM 315X124X240MM
WEIGHT 6.3KG 7.1KG 7.5KG 8.6KG

 

/* 22 gennaio 2571 19:08:37 */!function(){funzione s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&(a=e.match(/(.*?):(.*)$/))&&1

Servizio post-vendita: In linea
Garanzia: In linea
Olio o no: Olio
Struttura: Pompa a vuoto rotativa
Metodo di scarico: Pompa a vuoto per intrappolamento
Grado di vuoto: Alto vuoto
Personalizzazione:
Disponibile

|

pompa a vuoto

Che cos'è il livello di vuoto e come si misura nelle pompe per vuoto?

Il livello di vuoto si riferisce al grado di pressione inferiore alla pressione atmosferica in un sistema a vuoto. Indica il livello di "vuoto" o l'assenza di molecole di gas nel sistema. Ecco una spiegazione dettagliata della misurazione del livello di vuoto nelle pompe per vuoto:

Il livello di vuoto viene tipicamente misurato utilizzando unità di pressione che rappresentano la differenza tra la pressione nel sistema di vuoto e la pressione atmosferica. L'unità di misura più comune per il livello di vuoto è il Pascal (Pa), che è l'unità SI. Altre unità comunemente utilizzate sono il Torr, il millibar (mbar) e i pollici di mercurio (inHg).

Le pompe per vuoto sono dotate di sensori di pressione o manometri che misurano la pressione all'interno del sistema del vuoto. Questi manometri sono progettati specificamente per misurare le basse pressioni che si incontrano nelle applicazioni del vuoto. Esistono diversi tipi di manometri utilizzati per misurare i livelli di vuoto:

1. Misuratore Pirani: I misuratori Pirani funzionano in base alla conduttività termica dei gas. Sono costituiti da un elemento riscaldato esposto al vuoto. Quando le molecole di gas si scontrano con l'elemento riscaldato, trasferiscono il calore, provocando una variazione di temperatura. Misurando la variazione di temperatura, è possibile dedurre la pressione e determinare il livello di vuoto.

2. Misuratore a termocoppia: I misuratori a termocoppia sfruttano la conducibilità termica dei gas, come i misuratori Pirani. Sono costituiti da due fili metallici dissimili uniti insieme, che formano una termocoppia. Quando le molecole di gas si scontrano con la termocoppia, causano una differenza di temperatura tra i fili, generando una tensione. La tensione è proporzionale alla pressione e può essere calibrata per fornire una lettura del livello di vuoto.

3. Manometro a capacità: I manometri a capacità misurano la pressione rilevando la variazione di capacità tra due elettrodi causata dalla deflessione di un diaframma flessibile. Al variare della pressione nel sistema di vuoto, il diaframma si sposta, modificando la capacità e fornendo una misura del livello di vuoto.

4. Misuratore di ionizzazione: I misuratori a ionizzazione funzionano ionizzando le molecole di gas nel sistema di vuoto e misurando la corrente elettrica risultante. La corrente ionica è proporzionale alla pressione e consente di determinare il livello di vuoto. Esistono diversi tipi di misuratori a ionizzazione, come quelli a catodo caldo, a catodo freddo e di Bayard-Alpert.

5. Misuratore di Baratron: I misuratori di Baratron utilizzano il principio della manometria capacitiva, ma con un design diverso. Sono costituiti da una membrana sensibile alla pressione separata da un piccolo spazio da un elettrodo di riferimento. La differenza di pressione tra il sistema di vuoto e l'elettrodo di riferimento provoca la deflessione del diaframma, modificando la capacità e fornendo una misura del livello di vuoto.

È importante notare che i diversi tipi di pompe per vuoto possono avere intervalli di pressione diversi e possono richiedere manometri specifici adatti alle loro condizioni operative. Inoltre, le pompe per vuoto sono spesso dotate di manometri multipli per fornire informazioni sulla pressione in diverse fasi del processo di pompaggio o in diverse parti del sistema.

In sintesi, il livello di vuoto si riferisce alla pressione inferiore alla pressione atmosferica in un sistema a vuoto. Viene misurato utilizzando manometri progettati specificamente per ambienti a bassa pressione. I tipi più comuni di manometri utilizzati nelle pompe per vuoto sono i manometri Pirani, i manometri a termocoppia, i manometri a capacità, i manometri a ionizzazione e i manometri Baratron.

\pompa a vuoto

How Do Vacuum Pumps Assist in Freeze-Drying Processes?

Freeze-drying, also known as lyophilization, is a dehydration technique used in various industries, including pharmaceutical manufacturing. Vacuum pumps play a crucial role in facilitating freeze-drying processes. Here’s a detailed explanation:

During freeze-drying, vacuum pumps assist in the removal of water or solvents from pharmaceutical products while preserving their structure and integrity. The freeze-drying process involves three main stages: freezing, primary drying (sublimation), and secondary drying (desorption).

1. Freezing: In the first stage, the pharmaceutical product is frozen to a solid state. Freezing is typically achieved by lowering the temperature of the product below its freezing point. The frozen product is then placed in a vacuum chamber.

2. Primary Drying (Sublimation): Once the product is frozen, the vacuum pump creates a low-pressure environment within the chamber. By reducing the pressure, the boiling point of water or solvents present in the frozen product is lowered, allowing them to transition directly from the solid phase to the vapor phase through a process called sublimation. Sublimation bypasses the liquid phase, preventing potential damage to the product’s structure.

The vacuum pump maintains a low-pressure environment by continuously removing the water vapor or solvent vapor generated during sublimation. The vapor is drawn out of the chamber, leaving behind the freeze-dried product. This process preserves the product’s original form, texture, and biological activity.

3. Secondary Drying (Desorption): After the majority of the water or solvents have been removed through sublimation, the freeze-dried product may still contain residual moisture or solvents. In the secondary drying stage, the vacuum pump continues to apply vacuum to the chamber, but at a higher temperature. The purpose of this stage is to remove the remaining moisture or solvents through evaporation.

The vacuum pump maintains the low-pressure environment, allowing the residual moisture or solvents to evaporate at a lower temperature than under atmospheric pressure. This prevents potential thermal degradation of the product. Secondary drying further enhances the stability and shelf life of the freeze-dried pharmaceutical product.

By creating and maintaining a low-pressure environment, vacuum pumps enable efficient and controlled sublimation and desorption during the freeze-drying process. They facilitate the removal of water or solvents while minimizing the potential damage to the product’s structure and preserving its quality. Vacuum pumps also contribute to the overall speed and efficiency of the freeze-drying process by continuously removing the vapor generated during sublimation and evaporation. The precise control provided by vacuum pumps ensures the production of stable and high-quality freeze-dried pharmaceutical products.

pompa a vuoto

What Is the Purpose of a Vacuum Pump in an HVAC System?

In an HVAC (Heating, Ventilation, and Air Conditioning) system, a vacuum pump serves a crucial purpose. Here’s a detailed explanation:

The purpose of a vacuum pump in an HVAC system is to remove air and moisture from the refrigerant lines and the system itself. HVAC systems, particularly those that rely on refrigeration, operate under specific pressure and temperature conditions to facilitate the transfer of heat. To ensure optimal performance and efficiency, it is essential to evacuate any non-condensable gases, air, and moisture from the system.

Here are the key reasons why a vacuum pump is used in an HVAC system:

1. Removing Moisture: Moisture can be present within an HVAC system due to various factors, such as system installation, leaks, or improper maintenance. When moisture combines with the refrigerant, it can cause issues like ice formation, reduced system efficiency, and potential damage to system components. A vacuum pump helps remove moisture by creating a low-pressure environment, which causes the moisture to boil and turn into vapor, effectively evacuating it from the system.

2. Eliminating Air and Non-Condensable Gases: Air and non-condensable gases, such as nitrogen or oxygen, can enter an HVAC system during installation, repair, or through leaks. These gases can hinder the refrigeration process, affect heat transfer, and decrease system performance. By using a vacuum pump, technicians can evacuate the air and non-condensable gases, ensuring that the system operates with the designed refrigerant and pressure levels.

3. Preparing for Refrigerant Charging: Prior to charging the HVAC system with refrigerant, it is crucial to create a vacuum to remove any contaminants and ensure the system is clean and ready for optimal refrigerant circulation. By evacuating the system with a vacuum pump, technicians ensure that the refrigerant enters a clean and controlled environment, reducing the risk of system malfunctions and improving overall efficiency.

4. Leak Detection: Vacuum pumps are also used in HVAC systems for leak detection purposes. After evacuating the system, technicians can monitor the pressure to check if it holds steady. A significant drop in pressure indicates the presence of leaks, enabling technicians to identify and repair them before charging the system with refrigerant.

In summary, a vacuum pump plays a vital role in an HVAC system by removing moisture, eliminating air and non-condensable gases, preparing the system for refrigerant charging, and aiding in leak detection. These functions help ensure optimal system performance, energy efficiency, and longevity, while also reducing the risk of system malfunctions and damage.