Medical Automatic Touch Screen Infusion Pump

Medical Automatic Touch Screen Infusion Pump

3.5″ TFT coloration and touch screen for easy see and hassle-free operation
Horizontal flat and compact style with anti-corrosion PBT material
Flexible stack by innovative integrated rail design
Exact shipping rate in increments of .01ml/h
On-line titration perform to modify stream rate in the course of procedure
CZPT Force Surveillance(DPS)
Understand syringe makes and measurement from 5ml to 60ml routinely
Multiple infusion modes:Only fee, V-T, R-T, Dose rate, Loading dose, Trapezia, Sequence and Interrupt Model
Dural CPU style assures the security of technique
Movement compensation to keep away from mistake brought on by pipeline tiredness
Anti-bolus operate for the basic safety of sufferers
Up to 2000 function logs
Anti-free flow to prevent liquids free flow when doorway retains open up
Daytime mode and night time time manner interchange instantly
Equally audible and visible alarm, and 9 level alarm sound adjustable
Voltage:one hundred to 240 VAC
Frequency:50Hz / 60Hz
CZPTery type:Rechargeable lithium-ion battery ten-15V two.5A
Charging Time:≤4 several hours
Functioning Time:≥6 hours
Display screen:three.five” TFT coloration and touch monitor
Monitor brightness:nine grade adjustable, producer default is the fifth quality

Energy CZPT:
Voltage: 100 to 240 VAC Frequency: 50Hz / 60Hz
Rated electricity: 35VA    
Rechargeable CZPTery:
CZPTery kind Rechargeable lithium-ion battery 10-15V two.5A
Charging Time ≤4 hours Working Time ≥6 hours
Operating CZPT:
Temperature: +5~+40ºC Relative humidity: 10%~90%
Atmospheric pressure: 70~106kPa    
Shipment and Storage CZPT:
Temperature: -thirty~+70ºC Relative humidity ten%~ninety%
Atmospheric pressure: 22~106khPa.    
Dimension and W8:
Size(L*W*H/mm): 240*a hundred seventy five*eighty Internet Fat : 1.80kg
Packing Dimension(L*W*H/mm): 414*238*154 Gross Excess weight: two.80 kg
Safety Prerequisite
Reference Standard: EN 60601-one:2006
EN 60601-1-two:2007EN 60601-one-6:2571EN 60601-one-eight:2007BS EN 62304-2006IEC60601-two-24:2012
Watertight quality: IPX3
Precision:
Infusion charge: (.1~2000) ml/h Fee increment: (.one-99.99)ml/h,.01ml/h(100.-999.9)ml/h,.1ml/h(one thousand-2000)ml/h,1ml/h
VTBI (.1-9999)ml VTBI Increment: (.one-ninety nine.ninety nine)ml,.01ml(100.-999.nine)ml,.1ml(one thousand-9999)ml, 1ml
Quantity accuracy: ± five% CZPT accuracy : ± .50%
VTBI time range: 00:00:01-ninety nine:59:59(h:M:S)
IV set manufacturer: Integrated 5 brands, help consumer extending and calibration
Bolus:
Bolus type: CZPTal Bolus and Guide Bolus
Bolus fee: (.1 -2000) ml/h
CZPTal Bolus VTBI: .1ml~5ml, increment .1ml
Preserve Vein Open up(KVO):
KVO rate range: (.one~five.)ml/h Increment: .1ml
When infusion is accomplished, it enter KVO mode automatically, KVO can be turned off.
Alarm:
Type of alarm : Three grade (Substantial, Medium and Low) audible and obvious alarm with text prompts9 ranges adjustable alarm beep sound.
Alarm content : AC power interruption, DC energy interruption, Reduced battery, Depleted battery, Forget reminder, Infusion around end, Infusion complete, Flow fee, Door open up, Technique exception, Upstream Occlusion, Bubble detection alarm
Bubble detection alarm A one bubble alarm for 25ul, 100ul, 250ul.Cumulated bubble alarm adjustable for 300ul/15min, 500ul/15min
Occasion Log:
Event log volume : 2000 situations
Event content material : CZPTally record alarm info and operation occasion, including start off injecting, injection concluded, fee modification, injection quantity and so forth.
Info Communication:
Data transmission interface: RS232WIFI for alternative
Infusion workstation: It can operate collectively with other pump as portion of infusion workstation
Show:
Monitor: 3.5″ TFT color and touch display
Screen brightness: nine quality adjustable, maker default is the fifth quality
Screen Material: Doing work position, VTBI, VI (Volume Infused), Time remaining, Real-time strain, Stress threshold, Alarm material, IV established brand and dimension, Power condition, Day, Time.
Drug Library:
Programmable It can program drug listing in accordance to client ask for, and the drug identify need to be in 32 words and phrases.
DERS Drug Mistake Revise Technique for intelligent and basic safety
Recognize:Drug Library must plan by consumer according nearby regulation and clinic needs.

 

 

Medical Automatic Touch Screen Infusion Pump

TAGs:

Mail: [email protected]

Professional production Roots Vacuum Pumps, rotary vane pump, rotary piston pump, liquid ring vacuum pump, Oil-free Air Compressor, Screw Compressor, Scroll Compressor Manufacturer and Supplier.