3.5″ TFT coloration and touch screen for easy see and hassle-free operation
Horizontal flat and compact style with anti-corrosion PBT material
Flexible stack by innovative integrated rail design
Exact shipping rate in increments of .01ml/h
On-line titration perform to modify stream rate in the course of procedure
CZPT Force Surveillance(DPS)
Understand syringe makes and measurement from 5ml to 60ml routinely
Multiple infusion modes:Only fee, V-T, R-T, Dose rate, Loading dose, Trapezia, Sequence and Interrupt Model
Dural CPU style assures the security of technique
Movement compensation to keep away from mistake brought on by pipeline tiredness
Anti-bolus operate for the basic safety of sufferers
Up to 2000 function logs
Anti-free flow to prevent liquids free flow when doorway retains open up
Daytime mode and night time time manner interchange instantly
Equally audible and visible alarm, and 9 level alarm sound adjustable
Voltage:one hundred to 240 VAC
Frequency:50Hz / 60Hz
CZPTery type:Rechargeable lithium-ion battery ten-15V two.5A
Charging Time:≤4 several hours
Functioning Time:≥6 hours
Display screen:three.five” TFT coloration and touch monitor
Monitor brightness:nine grade adjustable, producer default is the fifth quality
Energy CZPT: | ||||||||||
Voltage: | 100 to 240 VAC | Frequency: | 50Hz / 60Hz | |||||||
Rated electricity: | 35VA | |||||||||
Rechargeable CZPTery: | ||||||||||
CZPTery kind | Rechargeable lithium-ion battery 10-15V two.5A | |||||||||
Charging Time | ≤4 hours | Working Time | ≥6 hours | |||||||
Operating CZPT: | ||||||||||
Temperature: | +5~+40ºC | Relative humidity: | 10%~90% | |||||||
Atmospheric pressure: | 70~106kPa | |||||||||
Shipment and Storage CZPT: | ||||||||||
Temperature: | -thirty~+70ºC | Relative humidity | ten%~ninety% | |||||||
Atmospheric pressure: | 22~106khPa. | |||||||||
Dimension and W8: | ||||||||||
Size(L*W*H/mm): | 240*a hundred seventy five*eighty | Internet Fat : | 1.80kg | |||||||
Packing Dimension(L*W*H/mm): | 414*238*154 | Gross Excess weight: | two.80 kg | |||||||
Safety Prerequisite | ||||||||||
Reference Standard: | EN 60601-one:2006 EN 60601-1-two:2007EN 60601-one-6:2571EN 60601-one-eight:2007BS EN 62304-2006IEC60601-two-24:2012 |
Watertight quality: | IPX3 | |||||||
Precision: | ||||||||||
Infusion charge: | (.1~2000) ml/h | Fee increment: | (.one-99.99)ml/h,.01ml/h(100.-999.9)ml/h,.1ml/h(one thousand-2000)ml/h,1ml/h | |||||||
VTBI | (.1-9999)ml | VTBI Increment: | (.one-ninety nine.ninety nine)ml,.01ml(100.-999.nine)ml,.1ml(one thousand-9999)ml, 1ml | |||||||
Quantity accuracy: | ± five% | CZPT accuracy : | ± .50% | |||||||
VTBI time range: | 00:00:01-ninety nine:59:59(h:M:S) | |||||||||
IV set manufacturer: | Integrated 5 brands, help consumer extending and calibration | |||||||||
Bolus: | ||||||||||
Bolus type: | CZPTal Bolus and Guide Bolus | |||||||||
Bolus fee: | (.1 -2000) ml/h | |||||||||
CZPTal Bolus VTBI: | .1ml~5ml, increment .1ml | |||||||||
Preserve Vein Open up(KVO): | ||||||||||
KVO rate range: | (.one~five.)ml/h | Increment: | .1ml | |||||||
When infusion is accomplished, it enter KVO mode automatically, KVO can be turned off. | ||||||||||
Alarm: | ||||||||||
Type of alarm : | Three grade (Substantial, Medium and Low) audible and obvious alarm with text prompts9 ranges adjustable alarm beep sound. | |||||||||
Alarm content : | AC power interruption, DC energy interruption, Reduced battery, Depleted battery, Forget reminder, Infusion around end, Infusion complete, Flow fee, Door open up, Technique exception, Upstream Occlusion, Bubble detection alarm | |||||||||
Bubble detection alarm | A one bubble alarm for 25ul, 100ul, 250ul.Cumulated bubble alarm adjustable for 300ul/15min, 500ul/15min | |||||||||
Occasion Log: | ||||||||||
Event log volume : | 2000 situations | |||||||||
Event content material : | CZPTally record alarm info and operation occasion, including start off injecting, injection concluded, fee modification, injection quantity and so forth. | |||||||||
Info Communication: | ||||||||||
Data transmission interface: | RS232WIFI for alternative | |||||||||
Infusion workstation: | It can operate collectively with other pump as portion of infusion workstation | |||||||||
Show: | ||||||||||
Monitor: | 3.5″ TFT color and touch display | |||||||||
Screen brightness: | nine quality adjustable, maker default is the fifth quality | |||||||||
Screen Material: | Doing work position, VTBI, VI (Volume Infused), Time remaining, Real-time strain, Stress threshold, Alarm material, IV established brand and dimension, Power condition, Day, Time. | |||||||||
Drug Library: | ||||||||||
Programmable | It can program drug listing in accordance to client ask for, and the drug identify need to be in 32 words and phrases. | |||||||||
DERS | Drug Mistake Revise Technique for intelligent and basic safety | |||||||||
Recognize:Drug Library must plan by consumer according nearby regulation and clinic needs. |